A. The quantity of air passing through the last open crosscut shall be not less than 9,000 cubic feet per minute; provided, however, that the quantity of air reaching the last open crosscut in pillar-recovery sections may be less than 9,000 cubic feet per minute, if at least 9,000 cubic feet of air per minute is being delivered to the intake end of the pillar line.
B. The air current at working faces shall, under all conditions, have a sufficient volume and velocity to readily dilute and carry away smoke from blasting and any flammable or harmful gases and dust.
1. The quantity of air shall be at least 30,000 cubic feet per minute reaching the working face unless otherwise approved by the Chief; and
2. The velocity of air provided to control dust at designated locations on the longwall or shortwall face shall be maintained in accordance with the provisions of the mine ventilation plan approved by the Mine Safety and Health Administration.
D. Ventilation shall be maintained during the installation and removal of mechanized mining equipment.